{
  "id": "HC-MODEL-01",
  "status": "CONCEPT INPUT BRIEF",
  "equipment": "HCM-T01",
  "configuration": "HC-CFG-01-A-CONCEPT",
  "components": [
    {
      "id": "BODY",
      "name": "HCM-T01 monitor housing",
      "constraint": "White portable body; graphite bezel; blank screen; external housing only. No internal assemblies or clinical readings."
    },
    {
      "id": "DISPLAY",
      "name": "Blank training display",
      "constraint": "No patient traces, invented measurements or diagnostic state."
    },
    {
      "id": "HANDLE",
      "name": "Teal carry handle",
      "constraint": "Fixed external handle. Orange hold tag belongs only to challenge/held configuration."
    },
    {
      "id": "BASE",
      "name": "Grey pedestal",
      "constraint": "Stationary external support. No yoke tilt or dismantling operation is established."
    },
    {
      "id": "P1",
      "name": "Left accessory port",
      "constraint": "One circular keyed port on the equipment\u2019s LEFT side. Location and axis fixed across all states."
    },
    {
      "id": "C-A",
      "name": "Matched round trainer lead",
      "constraint": "Round keyed trainer connector. Positive fit is a scenario identity, not an OEM compatibility claim. Continuous grey cable."
    },
    {
      "id": "C-B",
      "name": "Different rectangular trainer lead",
      "constraint": "Rectangular incompatible identity/key. Always held clear of P1; never morph, seat, force or present as a successful fit."
    },
    {
      "id": "TAG-H",
      "name": "Training hold tag",
      "constraint": "Orange tag on the held branch only. Does not confer lockout/repair authority or release."
    },
    {
      "id": "NOTE",
      "name": "Equipment review note",
      "constraint": "Synthetic asset/configuration, discrepancy, HELD status, reviewer/next owner and acknowledgement. No personal or patient data."
    }
  ],
  "prompt": "Create an editable external-geometry concept of fictional HCM-T01 for nonclinical staff equipment training, using the supplied permitted reference images. Preserve the white portable housing, graphite bezel and blank screen, wide teal carry handle, stationary grey pedestal and sole circular keyed P1 port on the LEFT side. Name meshes BODY, DISPLAY, HANDLE, BASE, P1, C-A, C-B, TAG-H and NOTE, with continuous cables grouped under their respective connector. Keep round C-A separate from rectangular C-B. C-B must never seat in P1 or morph into C-A. Provide an assembled normal configuration and a held/challenge configuration with TAG-H; do not add the tag to the normal teaching branch. No patient imagery, medical traces, OEM logos, inferred internal anatomy, invented release tab, yoke tilt or clinical-ready state. Treat all dimensions and fit as unverified until the customer\u2019s permitted measurements and reviewer-approved inert-trainer references are supplied. Export a low-poly GLB with named components, stable IDs, pivots, normals and a source/version manifest. Do not claim a native capture or validated digital twin from illustrations.",
  "input_requirements": [
    "Permitted orthogonal front/back/left/right/top/base photos of the SAME exact trainer with scale reference",
    "Close macro views of P1, C-A and C-B including keys and source labels; no sensitive serial data",
    "Actual dimensions/coordinate convention and fixture relationship",
    "Approved external-motion references, start/end positions and no-go volumes",
    "Permission/owner record, source revision and reviewer",
    "Editable Mirror Direct source session and export rights"
  ],
  "acceptance": [
    "Stable named mesh IDs and hierarchy",
    "Source-linked screenshots of left P1 and distinct C-A/C-B",
    "No invented geometry presented as measured",
    "Explicit normalized concept units until measured",
    "GLB loads, orbits, selects parts and downloads consistently",
    "Human review of clearances and permitted external motion before any fit lesson"
  ],
  "genesis": {
    "lesson_id": "HC-GEN-01-CONCEPT",
    "actual_runtime_built": false,
    "launch_url": null,
    "briefing": {
      "task": "Confirm HCM-T01 / HC-CFG-01-A-CONCEPT / HC-MON-01 A CONCEPT; inspect equipment and source; identify the next safe training action.",
      "roles": [
        "Synthetic learner T01",
        "Educator/reviewer",
        "Receiving colleague"
      ],
      "prerequisite": "Educator-approved inert/digital trainer, source procedure and rubric. No live clinical equipment."
    },
    "show_me": [
      "Name BODY, P1, C-A and C-B in the same assembly.",
      "Use the approved matched branch to show alignment/axial motion only when reference approval exists.",
      "Present the C-B challenge without insertion. Demonstrate HOLD, a source-linked explanation and closed-loop equipment-only handover."
    ],
    "train_me": [
      "Prompt configuration/source confirmation.",
      "Ask learner to select P1 and compare the two lead identities.",
      "Provide educator-authored hints after a wrong choice; preserve the held state.",
      "Practise the equipment restriction, next owner and receiver repeat-back."
    ],
    "assess_me": {
      "meaningful_wrong_choice": "Learner selects Continue/insert while C-B is presented.",
      "hold": "Block the digital attempted seating; show the mismatch cue and require a reason plus reviewer handover. Do not simulate a forced successful fit.",
      "recovery": "Return C-B to its separate tray, name the exact mismatch/source gap, record HELD and confirm educator ownership. Repeat with coaching if necessary.",
      "feedback": "Explain which component/configuration cue was missed; distinguish action evidence from missing compatibility/instrument evidence.",
      "rubric": [
        "Correct equipment/configuration/source identification",
        "Correct P1/C-A/C-B selection",
        "No attempted C-B insertion",
        "Clear HOLD reason and unresolved evidence",
        "Receiver repeat-back and sender confirmation",
        "No false clinical/equipment release"
      ],
      "scoring": "Educator-approved criteria and critical-fail/reset rules required; no score or measured result invented in the website."
    },
    "outputs": [
      "Versioned lesson linked to the exact model and procedure",
      "Named event log and synthetic review record",
      "Human-reviewed feedback and separate equipment status",
      "Actual authenticated Genesis URL plus access label after Jan\u2019s build and acceptance"
    ]
  },
  "missing_inputs": [
    {
      "id": "G1",
      "item": "Permitted multi-view measured source of an exact designated physical/inert trainer",
      "blocks": "Dimensional fidelity and any real fit claim"
    },
    {
      "id": "G2",
      "item": "Approved trainer procedure, compatibility/source record and revision owner",
      "blocks": "Approved operating SOP and accepted movement sequence"
    },
    {
      "id": "G3",
      "item": "Named editable Mirror Direct model/session/export and export permission",
      "blocks": "Native model provenance"
    },
    {
      "id": "G4",
      "item": "Approved no-go volumes, cable constraints and motion/pivots",
      "blocks": "Safe external-action animation or collision/fit lesson"
    },
    {
      "id": "G5",
      "item": "Educator/biomedical rubric, stop/reset policy and acceptance review",
      "blocks": "Assessment thresholds and training acceptance"
    },
    {
      "id": "G6",
      "item": "Jan-built Genesis lesson and authenticated learner access URL",
      "blocks": "Actual Healthcare simulator launch"
    },
    {
      "id": "G7",
      "item": "Supported device/runtime and customer permission for capture/reuse",
      "blocks": "Any customer-specific Field-IQ or learning-release claim"
    }
  ]
}
